Pursuant to NMCP regulations, facilities must report mercury emissions and the mercury co-product collected annually. Annual reports are received by the NDEP in the month of March, each year. The NDEP reviews the data submittals and aggregates the data into a spreadsheet report by July 1st, each year. Mercury emissions are calculated for every thermal unit, which is not De Minimis, using the most recent NDEP-approved stack test emission factor with actual throughput (production) values for the year. The Annual Emissions Reporting document describes the emissions reporting protocol and the NMCP Method 29 Source Test Guidelines contains the Method 29 source test parameters. Learn more about Method 29...

  

TRI Reporting Is Different Than NMCP Reporting

Under the US EPA Toxic Release Inventory Program (TRI), the threshold for facilities to report mercury (mercury compounds) is 10 lbs per calendar year. TRI defines a mercury compound as “any unique chemical substance that contains mercury as part of the chemical’s infrastructure.” TRI reporting calculates emissions from releases to air (fugitive and point sources), water discharges, land, transfers off site and other waste management activities.

The NMCP requires annual mercury emissions reporting from thermal units only (point sources). The NMCP has explicit testing and data requirements that differ from TRI. The NMCP only allows the use of a US EPA Reference Test Method 29, approved by the NMCP, from the same calendar year as the reporting year. An NMCP-approved test consists of: an NMCP-approved protocol, an NMCP-witnessed test and an NMCP-approved test report. A facility may use an NMCP-approved source test for TRI reporting, but other data sources acceptable forTRI reporting are not acceptable for NMCP reporting. Therefore, TRI and NMCP data values may be different for the same unit.

Total Reported Mercury Emissions by Year

This chart displays total mercury emissions using data from the Nevada Mercury Control Program (NMCP), the Voluntary Mercury Reduction Program (VMRP), and data from the US EPA's Toxic Release Inventory (TRI).

Below is a table of total reported mercury emissions by facility and calander year (CY). For more detailed reports in PDF format, click on the calander year heading (i.e., CY2006).

Nevada Mercury Control Program Anual Emissions Summary
Source CY 20061
(lbs of Hg)
CY 2007
(lbs of Hg)
CY 20082
(lbs of Hg)
CY 20093
(lbs of Hg)
CY 2010
(lbs of Hg)
CY 2011
(lbs of Hg)
CY 2012
(lbs of Hg)
CY 2013
(lbs of Hg)
CY 2014
(lbs of Hg)
CY 2015
(lbs of Hg)
Newmont - Twin Creeks (#2218) 434.37 929.93 1679.19 425.76 178.84 452.17 695.20 148.52 68.41 20.36
Newmont - Phoenix (#2247) 2.31 0.46 0.81 1.31 0.38 0.37 0.37 0.54 0.58 0.58
Newmont - Lone Tree (#2251) 622.10 148.10 67.13 7.21 3.02 1.88 1.88 1.88 1.88 1.88
Newmont - Gold Quarry (#2219) 310.69 504.42 422.41 280.69 397.13 222.61 231.85 96.63 115.91 190.35
Newmont - Midas (#2253) 17.18 4.25 41.34 6.44 14.23 32.08 21.83 16.36 2.62 3.07
Barrick - Bald Mountain (#2246) 204.30 57.41 278.32 5.90 7.82 3.22 3.15 3.64 3.64 3.12
Barrick - Goldstrike (#2221) 616.76 708.66 166.06 369.78 266.93 630.55 334.98 386.03 227.30 263.03
Barrick - Turquoise Ridge (#2249) 10.68 4.97 4.95 4.95 4.95 4.95 4.95 4.95 4.74 4.66
Barrick - Ruby Hill (#2252) 28.78 35.22 1.39 7.29 34.42 11.14 1.38 1.38 1..38 1.38
Barrick - Cortez (#2220) 166.71 208.05 75.86 1.39 5.19 5.18 4.22 15.76 2.22 6.18
Queenstake Resources (#2217) 293.92 1966.39 219.97 138.97 34.95 69.87 29.86 26.60 13.49 96.92
Rawhide Mining Company (#2245) 351.59 39.56 13.09 12.00 37.64 78.51 7.12 0.07 0.19 0.39
Hycroft Resources (#2255) DNO(4) DNO(4) DNO(4) 4.53 4.52 4.52 4.48 4.50 5.84 6.07
Antler Peak Gold, Inc. (#2248) DNO(4) DNO(4) 0.28 0.28 0.02 0.00 3.71 0.03 0.01 DNO(4)
Coeur Rochester (#2242) 2.89 137.10 9.91 4.41 2.64 3.35 3.26 2.64 2.19 4.30
Florida Canyon Mining (#2256) 440.74 19.00 162.31 49.61 111.81 51.73 8.24 4.23 4.13 26.41
Round Mountain Gold (#2250) 57.06 59.67 8.32 4.59 4.45 6.64 4.20 4.71 9.06 5.47
Marigold Mining Company (#2254) 908.06 5.23 10.49 4.45 9.34 11.17 2.12 7.56 3.37 34.65
Borealis Mining (#2228) DNO(4) DNO(4) DNO(4) DNO(4) DNO(4) DNO(4) 12.05 0.04 0.03 3.94
Mineral Ridge (#2222) DNO(4) DNO(4) DNO(4) DNO(4) DNO(4) 2.13 2.13 2.99 2.99 2.99
Plum Mining (#2690) DNO(4) DNO(4) DNO(4) DNO(4) DNO(4) 0.03 0.28 0.98 0.07 0.23
Manhattan Mining (#2303) DNO(4) 4.10 4.10 4.10 4.10 4.10 4.47 4.47 0.00 0.36
Aurum Joint Venture, LLC (#2638) DNO(4) DNO(4) DNO(4) 2.80 2.80 2.80 2.80 2.80 2.80 0.00
Noble Technologies Corporation (#2701) DNO(4) DNO(4) DNO(4) DNO(4) 4.00 4.00 4.00 4.00 4.00 DNO(4)
Tonkin Springs, LLC (#2726) DNO(4) DNO(4) DNO(4) DNO(4) 4.92 4.92 4.92 4.92 4.92 4.92
Total (lbs Hg) 4468.15 4832.50 3165.93 1336.46 1134.15 1607.94 1393.42 748.63 484.21 686.19

12006 Reporting Year

For the 2006 reporting year, not all thermal units had been stack tested for mercury emissions. Only Tier-1 units had the requirement to test prior to December 31, 2006; Tier-2 units began testing in the 2007 calendar year. Facilities which had not tested were instructed to use an emission factor from a similar unit in industry as a "surrogate emission factor." Later testing demonstrated that many of the surrogate values were quite different from tested values; thus the 2006 reported emission totals are coarse.

22008 Reporting Year

Note that 2 facilities had tests invalidated (Barrick Goldstrike and Ruby Hill), and 1 was not able to complete testing for all of its units due to an unexpected shutdown (Queenstake, Jerritt Canyon). The invalidated and untested units are displayed with red, blank cells in the reporting spreadsheet. Only valid 2008 test values may be used for the purpose of 2008 reporting. For the purpose of estimation, these red cell values may be populated for the purpose of emissions estimation (only) by using a valid test from an alternate year.

32009 Reporting Year

Note that two facilities did not have test data for all their thermal units in the 2009 reporting year. The untested units are displayed with red, blank cells in the reporting spreadsheet with corresponding explanations. Only valid 2009 test values may be used for the purpose of 2009 reporting.

4Facility Did Not Operate (DNO) any thermal units in years indicated.